| PRAMAC S 9000 |
 |
Item code: PD882TRA000

(purely indicative picture) |
Main features
| Rated maximum power (LTP) |
: |
8,2 kW |
| Rated prime power (PRP) |
: |
7,6 kW |
| Phases |
: |
3 Y |
| Voltage |
: |
230, 400 V |
| Frequency |
: |
50 Hz |
| Engine manufacturer |
: |
Ruggerini |
| Fuel |
: |
Diesel |
| Starting system |
: |
Electric |
S Series
Think of the right attributes for the power your activity demands. The
S Series offers reliability and performance, for the most demanding
applications. |
| Single-phase maximum power (LTP) |
6,77 kVA |
| Single-phase maximum power (LTP) |
6,1 kW |
| Single-phase prime power (PRP) |
3,67 kVA |
| Single-phase prime power (PRP) |
3,3 kW |
| Single-phase continuous power (COP) |
3,33 kVA |
| Single-phase continuous power (COP) |
3 kW |
| Rated maximum power (LTP) |
10,26 kVA |
| Rated maximum power (LTP) |
8,2 kW |
| Rated prime power (PRP) |
9,54 kVA |
| Rated prime power (PRP) |
7,6 kW |
| Rated continuous power (COP) |
8,83 kVA |
| Rated continuous power (COP) |
7,06 kW |
| Rated current at COP |
12,7 A |
| Phases |
3 Y |
| Voltage |
230, 400 V |
| Rated power factor |
0,8 PF |
| Frequency |
50 Hz |
| Battery charger voltage |
n.a. |
| Battery charger current |
n.a. |
| Panel location |
On frame |
| Frame type |
Tubular |
| Compliancy certification |
CE |
|
| Engine manufacturer |
Ruggerini |
| Model |
MD150 |
| Stroke |
4 |
| Fuel |
Diesel |
| Number of cylinders and disposition |
2, inline |
| Displacement |
654 cm³ |
| Air intake |
Natural |
| Starting system |
Electric |
| Nominal operating speed |
3000 rpm |
| Speed governor |
Mechanical |
| Continuous power COP |
8,6 kW |
| Prime power PRP |
9,3 kW |
| Standby power LTP |
10 kW |
| Lube oil capacity |
1,8 l |
| Fuel consumption at 75% load |
2 l/h |
| Electric circuit voltage |
12 V |
|
| Alternator specifications |
| Alternator manufacturer |
MeccAlte |
| Model |
T20FS-130/A |
| Poles |
2 |
| Revolution speed |
3000 rpm |
| Voltage |
400 V |
| Frequency |
50 Hz |
| Efficiency at 75% load |
82,1 % |
| Maximum admitted overload |
10% for 1 hour every 6 hours of running time S2 |
| Voltage regulation system |
Compound |
| Protection grade |
IP 23 |
|
| Skid mounting |
No |
| Fuel tank location |
On frame |
| Fuel tank capacity |
24 l |
| Automatic supplementary tank VV.FF. |
No |
| Running time at 75% COP |
12,02 h |
| Measured acoustic power (LWA) at 4 mt |
n.a. |
| Noise level at 7 m |
n.a. |
| Guaranteed noise level (LWA) |
n.a. |
| Operating conditions |
-5 ~ +45 °C |
|
| Length |
970 mm |
| Width |
600 mm |
| Height |
690 mm |
| Dry weight |
148 kg |
|
| Ammeter |
No |
| Frequency meter |
No |
| Hourmeter |
No |
| Isometer |
Optional |
| Voltmeter |
No |
| Voltage presence indicator |
No |
| Fuel level gauge |
No |
| Lube oil pressure gauge |
No |
| Lube oil pressure indicator |
Yes |
| High temperature indicator |
No |
| Water thermometer |
No |
| Electronic speed regulator (± 0,25%) |
No |
| Remote control (up to 40 m) |
Optional |
| Ecologizer |
No |
| Star-Delta switch |
No |
| Connector for AMF (Automatic Mains Failure) panel |
No |
| AMF (Automatic Mains Failure) panel |
Optional |
| SAS (automatic start system) |
No |
| Engine oil preheater |
No |
| Automatic engine shut down system |
No |
| Overspeed shutdown |
No |
| High temperature engine shut down |
No |
| Emergency stop |
No |
| Thermal protection |
No |
| Magnetothermic protection |
Yes |
| Minimum-maximum voltage relay |
No |
| 115-230 voltage switch |
No |
| ELCB (Earth Leakage Circuit Breaker) |
Optional |
| Lube oil guard |
No |
| Wheels and handles |
Optional |
| Lifting kit |
No |
| Job site trailer |
No |
| Road trailer |
No |
|
| CEE 3P+N+T 400V 16A |
1 |
| SCHUKO 230V 16A |
1 |
|
Technical specifications are subject to change without notice. Consult your local PRAMAC representative for more information.
|