Main features

Rated maximum power (LTP)  :  4,3 kW
Rated prime power (PRP)  :  4,3 kW
Phases  :  1
Voltage  :  230 V
Frequency  :  50 Hz
Engine manufacturer  :  Robin
Fuel  :  Gasoline
Starting system  :  Electric


P Inverter Series

The right power to supply equipment sensitive to voltage surges.

Technical specifications Standard equipment, options and accessories
Main specifications
Single-phase maximum power (LTP) n.a.
Single-phase maximum power (LTP) n.a.
Single-phase prime power (PRP) n.a.
Single-phase prime power (PRP) n.a.
Single-phase continuous power (COP) n.a.
Single-phase continuous power (COP) n.a.
Rated maximum power (LTP) 4,3 kVA
Rated maximum power (LTP) 4,3 kW
Rated prime power (PRP) 4,3 kVA
Rated prime power (PRP) 4,3 kW
Rated continuous power (COP) 3,8 kVA
Rated continuous power (COP) 3,8 kW
Rated current at COP 16,5 A
Phases 1
Voltage 230 V
Rated power factor 1,0 PF
Frequency 50 Hz
Battery charger voltage 12 V
Battery charger current 8,3 A
Panel location Canopied
Frame type Canopied
Compliancy certification CE
Engine specifications
Engine manufacturer Robin
Model EX27
Stroke 4
Fuel Gasoline
Number of cylinders and disposition 1, inclination angle
Displacement 265 cm³
Air intake Natural
Starting system Electric
Nominal operating speed 3600 rpm
Speed governor Mechanical
Continuous power COP 5,1 kW
Prime power PRP 5,6 kW
Standby power LTP 6,3 kW
Lube oil capacity 1,1 l
Fuel consumption at 75% load 1,66 l/h
Electric circuit voltage 12 V
Alternator specifications
Alternator manufacturer Robin
Model n.a.
Poles 16
Revolution speed n.a.
Voltage 230 V
Frequency 50 Hz
Efficiency at 75% load 70 %
Maximum admitted overload 10% for 1 hour every 6 hours of running time S2
Voltage regulation system Inverter
Protection grade IP 23
Additional information
Skid mounting No
Fuel tank location On canopy
Fuel tank capacity 12,8 l
Automatic supplementary tank VV.FF. No
Running time at 75% COP 7,73 h
Measured acoustic power (LWA) at 4 mt 91,7 dBA
Noise level at 7 m 62 dBA
Guaranteed noise level (LWA) 93 dBA
Operating conditions -15 ~ +40 °C
Dimensional data
Length 580 mm
Width 527 mm
Height 618 mm
Dry weight 74 kg

Technical specifications are subject to change without notice. Consult your local PRAMAC representative for more information.